Product description

HOMOTH TE-OAE 4000 PC module treads new paths in evaluating results of measured Otoacoustic Emissions. All measured data is classified according to signalstatistic and signaldynamic features. The result is transmitted to an expert system as parameter vectors. The expert system, containing more than 10.000 evaluated OAE measurements, compares all parameter vectors with the stored samples. All data and measured curves can be stored on harddisc, if the device is connectet to a PC. For printouts, an extremely fast digital-printer, working very noiseless and economical is used. The analysis module consists of an artificial neuronal network, supplemented by modern fuzzy logic. The result is transmitted to the personal computer, via USB port, and is presented on the monitor. Using the HOMOTH expert system an objective result of a hearing test, comparable to subjective evaluation of an experienced OAE expert, is possible. The actual measured data is compared and evaluated automatically within a few seconds. So everybody is able to use the special knowledge of many OAE experts. The analysis module evaluates the signalstatisticand the signaldynamic parameters, the artefacts are eleminated and the characteristic components of the emissions are isolated. The screen shows the SOAE, TE-OAE and the artefacts. Therefore the HOMOTH expert system also allows the untrained user of the OAE system, a very high safety regarding the statement of result. As for a classical OAE measurement, all relevant diagrams are displayed at the monitor. The HOMOTH TE-OAE expert connects all advantages of the classical OAE diagnostic with the most modern computer technology as neuronal networks and fuzzy logic.

Technical specifications

system:PC- Module System requirements:Pentium PC min. 800 MHz, USB 2.0 Port, Windows XP, 7, 8, 10 (32/64 Bit) Stimulus:clickquartett ( 3 pos. / 1 neg. ) 20 ms rate Results presentation:time window with two correlating measurements in different colour, time window with the spontaneous emissions, maxima of the emissions, realtime spectrum of the stimulus, spectrum of the emissions / spectrum of the noise , ZF correlation F/t parameter for SNR, stability, reproduction numbers of the artefacts and the given stimuli automatical analysis of the results after the expert system (certain positiv, positiv, poor positiv, negativ, certain negativ) Intensity:approx. 80 dB with automatical gain control Probe:• miniature design with pressure ventilation • realtime probe control via FFT Converter:12 Bit / 100 kHz Amplifier:80 dB with automatical gain setting Measurement:manual adjustable 16,32,64,128,256,512 clickquartetts Artefacts:automatical artefact recognition and elimination Power supply:13,2 V, external power supply 100-240 V, 50/60 Hz, 15 W Probe cable:2000 mm, high flexible with a patients clip for fastening Dimensions:330 x 80 x 265 mm (WxHxD) Weight:2,1 kg Accessories:1 miniature probe, complete with 24 ear plugs in 6 different sizes, USB-cable, power supply, installations-CD, manual